PE Anti-Human CD23 Antibody[EBVCS2]
规格: | / 20Tests / 100Tests / 100Tests×2 |
价格: | / ¥1020 / ¥2160 / ¥3720 |
货号:E-AB-F1382D
货期:咨询
应用: FCM
Isotype: Mouse IgG1, κ
宿主: Mouse
Antigen Information
Alternate Names | Leu-20, FcεRII, IgE Fc Receptor, BLAST-2, B6, Low affinity IgE receptor |
Swissprot | P06734 |
Gene ID | 2208 |
References |
1. Ludin C, et al. 1987. EMBO J. 6:109.
2. Delespesse G, et al. 1992. Immunol. Rev. 125:77. 3. Flores-Romo L, et al. 1993. Science 261:1038. 4. Armant M, et al. 1994. J. Exp. Med. 180:1005. |
Product Details
Form | Liquid |
Clone No. | EBVCS2 (See Other Available Formats) |
Host | Mouse |
Isotype | Mouse IgG1, κ |
Isotype Control | PE Mouse IgG1, κ Isotype Control[MOPC-21] [Product E-AB-F09792D] |
Reactivity | Human |
Application | FCM (See the Application Description) |
Storage Buffer | Phosphate buffered solution, pH 7.2, containing 0.09% sodium azide and 1% BSA. |
Recommended Use | Each lot of this antibody is quality control tested by immunofluorescent staining with flow cytometric analysis. The amount of the reagent is suggested to be used 5 μL of antibody per test (million cells in 100 μL staining volume or per 100 μL of whole blood). Please check your vial before the experiment. Since applications vary, the appropriate dilutions must be determined for individual use. |
Shipping | Biological ice pack at 4℃ |
Stability & Storage | Keep as concentrated solution. Store at 2~8°C and protected from prolonged exposure to light. Do not freeze. Centrifuge before opening to ensure complete recovery of vial contents. This product is guaranteed up to one year from purchase. |
Conjugation | PE |
PE is designed to be excited by the Blue (488 nm), Green (532 nm) and Yellow-Green (561 nm) lasers and detected using an optical filter centered near 575 nm (e.g., a 585/42 nm bandpass filter). | |
|
Recommended Use
Each lot of this antibody is quality control tested by immunofluorescent staining with flow cytometric analysis. The amount of the reagent is suggested to be used 5 μL of antibody per test (million cells in 100 μL staining volume or per 100 μL of whole blood). Please check your vial before the experiment. Since applications vary, the appropriate dilutions must be determined for individual use.
Related Protocols
Troubleshooting
References
1. Ludin C, et al. 1987. EMBO J. 6:109.
2. Delespesse G, et al. 1992. Immunol. Rev. 125:77.
3. Flores-Romo L, et al. 1993. Science 261:1038.
4. Armant M, et al. 1994. J. Exp. Med. 180:1005.
2. Delespesse G, et al. 1992. Immunol. Rev. 125:77.
3. Flores-Romo L, et al. 1993. Science 261:1038.
4. Armant M, et al. 1994. J. Exp. Med. 180:1005.